Flow Meter Avery Hardoll 8 Inch CM5500

Flow Meter Avery Hardoll 8 Inch CM5500 (4 Capsule) , distributor Flow Meter Avery Hardoll yang tepat,Tersedia Berbagai Tipe & Spesifikasi Produk Flow Meter Avery Hardoll 8 Inch CM5500 4 Capsule Dengan Kualitas Asli & Terpercaya. Jika ingin beli Flow Meter Avery Hardoll 8 Inch CM5500 4 Capsule dengan harga grosir,Kami banyak pilihan, bergaransi & melayani pengriman ke seluruh wilayah indonesia
Jual Flow Meter Avery Hardoll 8 Inch CM5500 (4 Capsule),Flow Meter Avery Hardoll 8 Inch CM5500 4 Capsule,Distributor Flow Meter,Flow Meter Avery Hardoll 8 Inch CM5500 4 Capsule, harga Flow Meter Avery Hardoll,Flow Meter Avery Hardoll 8 Inch CM5500 4 Capsule indonesia,agen Flow Meter Avery Hardoll,Flow Meter Avery Hardoll jakarta,Flow Meter Avery Hardoll 8 Inch CM5500 4 Capsule terbaik,Flow Meter Avery Hardoll murah.
Banyak perusahaan industri yang menggunakan Flow Meter Avery Hardoll 8 Inch CM5500 4 Capsule untuk menghitung sejumlah massa yang lewat dalam sebuah bidang/area dalam satuan waktu. Ada beberapa cara yang dapat ditentukan untuk medapatkan type dan model flow meter yang anda butuhkan, Untuk Lebih Lengkapnya dan Untuk Cara Order Produk Atau Info Harga …!!!
Hubungi CS Kami Melalui Kontak Telp. 021-29134048 / 0852 6903 3192 / email. rademateknik@gmail.com

Katalog-Avery_Hardoll_CM_Series_

Deskripsi

Flow Meter Avery Hardoll 8 Inch CM 5500 (4 Capsule)

Spesifikasi :

Meter Size : 8 Inch
Model : CM 5500
Flow Rate :
120 to 1200 (Imp Gall), 550 to 5500 (Lpm), 33 to 330(m3/hr)
Flanges : ASA 150 FF/RF Steel

KALIBRATION :

Calibration adjustment is provided to minimize the meter error at any selected flowrate. Adjustment isstepless; no gear changing is necessary; and the calibration screw is easily accessible after breaking aseal and removing a sealing screw.All meters are tested to 300 psi (21 bar).All Avery-Hardoll meters are tested before despatch at a range of flowrates and test certificates can besupplied if requested.The fluid used for testing is odorless kerosene.Specific gravity at 60/60ºF, 15/15ºC = 0.8Viscosity at 60ºF, 15ºC = 2.4 centistokes.Suggested correction to be made to the calibrating mechanism when used with products with differentviscosities as follows:Gasoline+ 0.1%Kerosene0.0%Gas Oil– 0.1%Fuel Oil0.22%+means increase counter readingsmeans decrease counter reading